Port channel uplink failure and recovery on Fabric Interconnects

Fabric Interconnects can connect to northbound Nexus switches either directly or using a port channel/vPC. Port channel configuration, which not only load-balances bandwidth utilization but also avoids unnecessary reconvergence in the case of partial link failures, is recommended as multiple uplink ports can be aggregated.

Use the following procedure to verify northbound port channel configuration and the operational state:

  1. Log in to UCS Manager.
  2. Click on the LAN tab in the navigation pane.
  3. In the LAN Cloud tab, expand Fabric A and Port Channels.
  4. In the work pane, the Status of Port Channels is shown in the General tab as follows:
  1. The Ports tab shows member ports and the Faults tab shows any faults as shown in the following screenshot:

The following screenshot shows the error message that is displayed when a port channel cannot be brought up due to a mismatch in speed between the Fabric Interconnects and uplink Nexus ports:

Some other common upstream port channel issues and recommended solutions are as follows:

Issue Recommended solution

Port channel does not come up.

Verify cable connectivity and look for any physical SFP failure.

Verify that there is no protocol or speed mismatch between the connected ports.

Verify individual connectivity by removing the port channel configuration.

Port channel member failure. The error message in GUI is membership-down.

Verify cable connectivity and look for any physical SFP failure.

Verify any speed mismatch and correct the issue.