23.5 Endmember Extraction

The reflectance Cuprite data scene in Figure 1.12 was used for experiments by PBS with BP/ID-BD to investigate an application in endmember extraction where a threshold value ε for ID-BD was empirically set to 0.01 to remove correlated bands. After BP/ID-BD, only 95 spectral bands were retained. Table 23.1 tabulates the first 50 spectral bands after BP/ID-BD using 7 BP criteria: variance, SNR, skewness, kurtosis, entropy, ID, and negentropy. Interestingly, the interband correlation for this scene is clearly characterized by second-order statistics rather than by high-order statistics (HOS), where only a few bands are removed by ID-BD using three specific HOS criteria: kurtosis, ID, and negentropy.

Table 23.1 Seven BP criteria to produce the first 50 bands after BP/ID-BD with bands removed by ID-BD for Cuprite data by setting ε = 0.01.

50 BP/BD bands Bands removed by ID-BD
Variance 87/78/98/189/75/94/96/95/67/123/124/122/
120/125/117/114/129/112/54/131/46/40/
187/108/133/102/106/25/20/188/18/141/
143/142/145/140/146/144/139/147/16/
138/149/137/150/151/152/15/153/154
85/88/86/89/84/91/80/90/92/83/82/79/93/81/
99/97/77/76/100/74/73/72/101/71/70/69/
68/121/66/65/119/64/118/63/127/126/128/
62/116/115/61/113/59/60/58/57/55/56/
130/111/53/52/51/50/110/49/48/47/41/44/
43/45/42/39/38/109/37/36/132/35/34/33/
135/32/134/107/31/29/30/28/27/26/103/
104/24/23/105/22/21/19/17
SNR 68/26/89/20/18/53/76/39/16/15/14/114/120/
112/117/124/122/12/123/125/11/129/9/97/
131/108/96/8/94/95/7/133/6/5/106/149/
142/150/146/147/151/4/152/153/143/141/
145/3/144/155
71/67/69/70/72/66/73/65/74/25/27/23/24/28/
22/64/21/75/63/87/88/85/86/91/19/83/84/
42/29/90/52/17/49/43/54/51/38/50/62/45/
35/57/32/55/41/31/37/47/33/48/34/44/
113/36/56/82/118/13/93/119/46/30/115/
126/121/92/111/127/110/128/116/40/109/
61/10/130/98/77/99/100/81/132/60/58/59/
101/80/134/107/135/79/78/104/148/103
Skewness 2/1/3/4/5/6/7/8/9/11/12/14/184/15/185/183/
181/16/179/178/180/182/177/170/171/18/
159/169/20/158/176/157/186/172/156/25/
155/175/173/49/174/160/154/168/43/153/
167/166/152/64
10/13/17/19/21/22/23/24/26/30/27/31/28/32/
29/33/50/51/48/52/47/34/53/46/54/45/35/
44/55/56/42/36/57/37/41/38/39/40/58/59/
60/61/62/63
Kurtosis 2/3/1/4/5/6/7/8/9/185/181/183/184/179/178/
180/170/182/177/11/169/171/12/176/172/
14/159/158/168/157/156/175/155/15/154/
160/167/173/153/174/166/16/152/186/
151/165/150/164/18/161
10/13/17
Entropy 90/101/189/82/96/37/95/111/75/112/124/
187/117/126/123/122/46/107/188/174/25/
175/173/67/103/102/131/172/176/20/52/
177/105/171/18/168/134/169/178/179/
137/170/162/159/167/161/163/160/158/
136
92/88/99/89/91/93/86/87/100/85/84/98/83/
97/81/94/80/79/78/77/38/76/40/39/36/41/
35/113/110/109/42/34/114/120/115/121/
116/118/74/33/119/43/73/32/44/29/108/
72/45/31/28/125/128/127/30/71/27/129/
70/26/47/69/130/68/24/23/48/66/22/104/
65/49/60/63/21/64/61/59/62/50/106/58/
51/54/53/56/55/132/57/19/133/135/17
ID 1/2/3/5/153/154/152/4/151/150/9/6/8/185/
144/146/7/11/139/140/155/145/149/184/
156/12/182/183/147/142/180/143/165/
138/181/164/186/141/160/157/167/14/
170/166/163/158/169/179/15/161
10/148/13
Negentropy 2/3/1/4/5/6/7/8/9/185/181/184/183/179/178/
180/11/170/182/177/171/169/12/176/14/
159/172/158/157/15/168/156/175/155/
154/16/160/173/167/153/174/186/166/
152/151/165/18/150/164/161
10/13/17/19

Figure 23.1(a)–(g) shows the results of IN-FINDR-extracted mineral signatures among A, B, C, K, and M using BP/ID-BD-generated spectral bands given in Table 23.1, where the figures on the right and the left were obtained by PBS with/without using ID-BD, respectively. Also in Figure 23.1, a vertical line in each figure shows a cutoff threshold for img determined and set by DDA = 26 that was the largest value obtained by Huffman coding among five mineral signatures.

Figure 23.1 IN-FIND-extracted endmembers from Cuprire scene using PBS with different seven BP criteria with DDA = 26 (Huffman coding) and figures on the right and the left are obtained by PBS with/without using ID-BD, respectively.

img

img

img

Comparing Figure 23.1 with Figure 21.8, the results produced by BP/ID-BD-generated bands are different from the results the generated by using BP without BD. However, the improvement of endmember extraction was not really significant.

..................Content has been hidden....................

You can't read the all page of ebook, please click here login for view all page.
Reset
3.145.115.195