The battery storage in total watt-hours required for three days of autonomy tells
you how many watt-hours are required.
It does not tell you what the total watt-hour or amp-hour requirements are.
Those will be based upon DOD, which will need to be converted into amp-
hours at a specific hourly rating. This fine-tuning will tell you how many batteries
you will need at a specific voltage to meet the required 30,600 watt-hours
rating above.
Calculations of the battery requirements in amp-hours will need to be
matched against the number of batteries at a specific size in amp-hours. It will
require factoring in the nominal voltage required (12 Vdc, 24 Vdc, or 48 Vdc) to
meet both series and parallel requirements for the overall battery array, and it
may take looking at a number of battery options to meet the requirements you
have set for autonomy.
Step 3: PV System Array Sizing
Watt-hours per day × Battery Loss Factor ÷ Insolation = Array in DC watts
10,200 watt-hrs/day × 1.2 ÷ 6 peak sun hours/day (2) = 2,040 DC watts
This step indicates the number of DC watts required to meet the daily load for
battery storage.
It is 20 percent more energy than you need to run the load itself to fill the
batteries once.
It will require looking at the PV panels you are considering and finding an
acceptable size and voltage for string sizing that will come to the next step above:
2,040 DC watts of panels. Oversizing is better than undersizing, especially as you
continue the system sizing exercise.
It will then need to be upsized to bring the batteries to full charge because
you will always use some energy each day to bring the batteries to a 100 per-
cent SOC.
If you use a generator, it can provide the bulk charge to bring the batteries up
to where they need to be to top them off with PV. This must be considered in the
budget process, because although a generator may seem relatively inexpensive to
install, when you add the fuel and O&M over time, your cost for a kilowatt-hour
will be from $1.50 to $2.50. This is more than the cost of the energy from your
solar panels. Consider these numbers carefully, especially as fuel costs go up.
If the autonomy is for three days, and you wish to bring the system to full
charge, you will need to upsize the array by a predetermined percentage. Leaving
batteries discharged for extended periods of time will damage them and shorten
their life.
If you wish to have the batteries recharged in three days, you will need to
upsize the array by a third from 2,040 DC watts to 2,734 DC watts at full sun.
CHAPTER 6 Standalone PV Systems 129