P3.8. PMOS Lambda

LabVIEW Computations

Straight-line curve fit from active region data:

ID = Slope · VSD + IDo

λp = Slope/IDo kp = IDo/Veffp2

Procedure

  • Lambda.vi is configured for Enable Data Base Access to read the data from PMOSoutput.vi. Lambda.vi can read all of the Front Panel information in PMOSoutput.vi when a log of the Front Panel has been obtained.

  • From the Diagram of Lambda.vi, open PMOSoutput.vi. Obtain a data log of the Front Panel of the PMOSoutput.vi (under Operate Menu).

  • Run Lambda.vi to read the graph of measured data (from PMOSoutput.vi) and to plot the measured data from the active region. The VI obtains Kp and λp from these data, for each of the voltage sweeps. Note that Lambda varies. Compare the average Lambda value with that from PMOSparam.vi.

  • Click on Call PlotID_VSD.vi Green to bring up a plot of the active-region equation plot for –1/λp < VSD < VSDmax, compared with the measured data. Lambda.vi will be used in the Mathcad analysis file.